| Abstract: |
Fins are the cheapest way to speed up charging of latent heat stores, but in a side-heated enclosure a fin also reorganises the buoyancy-driven flow of the melt, so its height matters as much as its size. This study examines how the height of a single horizontal aluminium fin changes the full charging history of lauric acid in a 50 mm × 120 mm vertical enclosure whose side wall is held at 70 °C. Two-dimensional transient simulations with the enthalpy–porosity method and the Boussinesq approximation were verified by a mesh study and validated against published single-fin experiments. Melting over 175 min was compared for an enclosure without a fin and with a fin at dimensionless heights of 0.50 and 0.80, and the melt fractions were interpreted against a one-dimensional Neumann conduction solution. All cases pass from a conduction-dominated start to convection-dominated melting in which the melt stratifies and the last solid is left at the bottom, away from the heated wall. A mid-height fin divided the melt into two convection cells and sustained circulation in the lower half; it melted about 99% of the PCM in 175 min, against about 90% for the upper fin and 71% without a fin. Interpolated times to 70% melting were shorter by roughly 31% and 16%, respectively, and by 175 min the melt fraction was 2.6 and 2.4 times the conduction-only value, compared with 1.9 without a fin. A fin placed high in the enclosure mostly heats liquid that is already stratified. Fins in side-heated stores should therefore be positioned to supply heat to the lower region that natural convection reaches last. |